Model Number: HSF-SE-0003-04
Key Specifications/Special Features:
1. Pressure MPa: 0.05-10kg/cm22. Frequency detection error: ±10%3. Apply the liquid: 1-38°C purified water4. Flow detection method: hall sensor5. Minimum flow perception: 1.0L/min6. Allow the surrounding temperature: below 40 degrees Celsius7. Power supply specification, power: 5V DC8. Maximum resistance to hydrostatic pressure: 10kg/cm29. Lead the color:Red: power (power line, XH-K3 PIN1)White: output (output, XH-K3pin 2)Black: ground (ground electrode, XH-K3 pin3)
10. Wire specifications: UL 1007 #22 AWG
11. Length of the wire: 950 ±15mm
12. Connect the metal terminals: SXH-001T-P0.6, JST brand
13. Connector: XH-K3 (with lock, retaining appliance)
14. Outgoing line can sustain tension: 80N continues 10S
15. Maximum flow capacity 5L/min
Fast interface of 3/8-inch, hall element, flow sensor
There are three design patents (ZL201430079765. X) (ZL201420235311.1) (ZL201430079764.5) products
Small volume, quick installation, high precision accuracy data output
Action performance parameters of the table |
Flow/minute |
1L/minute |
1.5L/minute |
2.0L/minute |
2.5L/minute |
3.0L/minute |
3.5L/minute |
4L/minute |
4.5L/minute |
5L/minute |
Hz |
7.25 |
10.17 |
13.58 |
17.42 |
20.83 |
24.50 |
28.00 |
31.33 |
35.17 |
Hz(+10) |
7.98 |
11.18 |
14.94 |
19.16 |
22.92 |
26.95 |
30.80 |
34.47 |
38.68 |
Hz(+10) |
6.53 |
9.15 |
12.22 |
15.68 |
18.75 |
22.05 |
25.20 |
28.20 |
31.65 |